Multiple Amp Range LK MN2 Overload Relay Specification

  • Contact Form
  • 1NO+1NC
  • Contact Resistance
  • <50 m
  • Coil Voltage
  • N/A (Thermal Type)
  • Coil Power
  • N/A (Thermal Trip)
  • Protect Feature
  • Phase Failure, Overload, Manual/Auto Reset
  • Mechanical Life
  • Over 1,000,000 cycles
  • Dielectiric Strength
  • 2,500V AC for 1 minute
  • Contact Material
  • Silver Alloy
  • Power Consumption
  • Negligible/Passive Device
  • Working Temperature
  • -20C to +60C
  • Ambient Temperature
  • -5C to +55C
  • Product Type
  • Overload Relay
  • Insulation Resistance
  • > 100 M at 500V DC
  • Theory
  • Thermal Overload
  • Usage
  • Suitable for protection of electric motors against overload and phase failure
  • Contact Load
  • 6A (AC-15) / 3A (DC-13)
  • Operate Time
  • 1.2 Seconds (Standard)
  • Terminal Type
  • Screw Terminal
  • Rated Voltage
  • 690V AC
  • Supply Terminal
  • Top & Bottom Connect
  • Size
  • Standard Modular
  • Color
  • Black and Blue
  • Dimension (L*W*H)
  • Approx. 78mm x 45mm x 70mm
  • Weight
  • Approx. 120g
  • Frequency
  • 50/60Hz
  • Complies With
  • IS/IEC 60947-4-1
  • Ampere Range
  • Available in multiple amp ranges e.g. 0.63A-1A, 1A-1.6A, 1.6A-2.5A, 2.5A-4A, 4A-6A, etc.
  • Operation Indicator
  • Trip indicator provided
  • Interlocking
  • Available for mechanical/electrical interlock
  • Reset Type
  • Manual & Automatic Reset
  • Tripping Class
  • Class 10A
  • Mounting Type
  • Direct mount to contactor/DIN Rail Mountable
  • Enclosure
  • Flame Retardant Plastic
 

Multiple Amp Range LK MN2 Overload Relay Trade Information

  • Minimum Order Quantity
  • 250 Units
  • Supply Ability
  • 500 Units Per Month
  • Delivery Time
  • 10 Days
  • Main Domestic Market
  • All India
 

Multiple Amp Range LK MN2 Overload Relay About



Select the exceptional Multiple Amp Range LK MN2 Overload Relay and procure reliability for your electrical systems. This superlative product comes in a variety of amp ranges-making it a decorated choice for various protection needs. Designed for direct contactor/DIN rail mounting, it offers both manual and automatic reset options. Enjoy top-notch features such as operation indicators, phase failure protection, and compliance with IS/IEC 60947-4-1. Hot deal alert: experience more than 1,000,000 mechanical cycles, robust flame-retardant enclosure, and superior safety standards. Ideal for suppliers, traders, and wholesalers across India.

Versatile Applications for Commercial Settings

Multiple Amp Range LK MN2 Overload Relay is widely used by industrial experts, electricians, and maintenance engineers. Its adaptability makes it perfect for commercial settings such as factories, manufacturing units, and workshops. This relay is typically utilized to safeguard electric motors and machinery from overloads and phase failures, ensuring continuous operations. Whether used in new installations or retrofitting old systems, the device provides flexible protection compatible with varying currents, fitting diverse commercial and industrial usage scenarios.


Supply Details, Packaging, and Sample Logistics

We supply the Multiple Amp Range LK MN2 Overload Relay through dependable FOB ports across India. Each relay is securely packaged, adhering to robust industrial standards, ensuring safe delivery to customers. Our packaging details are tailored for bulk as well as individual orders. For queries about quotations or to request samples, our sample policy offers easy procedures for prospective buyers. Contact us to know about supply timelines and how you can receive detailed packaging options and prompt quotations.


FAQ's of Multiple Amp Range LK MN2 Overload Relay:


Q: How does the LK MN2 Overload Relay protect electric motors?

A: The LK MN2 Overload Relay safeguards electric motors by detecting overloads and phase failures, automatically tripping to prevent damage, and providing both manual and automatic reset options for continued protection.

Q: What is the process for selecting the correct amp range for my application?

A: To select the correct amp range, match your motor's rated current with one of the available ranges, such as 0.63A-1A, 1.6A-2.5A, or 4A-6A, ensuring precise overload protection and optimal performance for your equipment.

Q: Where can this relay be mounted for installation?

A: The LK MN2 Overload Relay can be directly mounted onto a contactor or attached to a DIN rail, offering flexibility and ease of installation for both compact and conventional panel setups.

Q: What are the commercial benefits of using this overload relay?

A: Commercial users benefit from enhanced motor safety, reduced downtime, mechanical/electrical interlock options, and a superlative mechanical life exceeding 1,000,000 cycles-all contributing to increased equipment reliability and operational efficiency.

Q: When should the operation indicator be checked on the device?

A: The operation (trip) indicator should be checked whenever a motor stops unexpectedly, as it signals overload conditions or phase failures, helping users diagnose issues rapidly and take corrective actions.

Q: What packaging and supply options are available for bulk orders?

A: For bulk procurement, the relays are individually packaged with robust protections, and supply is facilitated via major FOB ports. Detailed quotations and packaging options can be provided on request to meet specific customer requirements.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Electrical Relay Category

ABB Overload Relay

ABB Overload Relay

Minimum Order Quantity : 10 Units

Power Consumption : 2 W

Working Temperature : 25C to +60C

Color : Gray

Ambient Temperature : 25C to +60C

Supply Terminal : Bottom and Top

Pin Type Omron Relay

Pin Type Omron Relay

Minimum Order Quantity : 10 Units

Power Consumption : Approx. 0.5W

Working Temperature : 40C to +70C

Color : Transparent / Black

Ambient Temperature : 40C to +70C

Supply Terminal : Screw / Plugin socket

Multiple Range Amp LK MK1 Relay

Multiple Range Amp LK MK1 Relay

Minimum Order Quantity : 10 Units

Power Consumption : <2VA

Working Temperature : 10C to +55C

Color : Grey/Black

Ambient Temperature : 20C to +50C

Supply Terminal : Dual Supply Options

LK MN5 Overload Relay

LK MN5 Overload Relay

Minimum Order Quantity : 10 Units

Power Consumption : 2W

Working Temperature : 25C to +55C

Color : Black & White

Ambient Temperature : 5C to +40C

Supply Terminal : Top & Bottom



Back to top