Multiple Amp Range LK MN2 Overload Relay Specification

  • Contact Resistance
  • <50 m
  • Contact Material
  • Silver Alloy
  • Coil Voltage
  • N/A (Thermal Type)
  • Mechanical Life
  • Over 1,000,000 cycles
  • Contact Form
  • 1NO+1NC
  • Coil Power
  • N/A (Thermal Trip)
  • Power Consumption
  • Negligible/Passive Device
  • Ambient Temperature
  • -5C to +55C
  • Working Temperature
  • -20C to +60C
  • Protect Feature
  • Phase Failure, Overload, Manual/Auto Reset
  • Dielectiric Strength
  • 2,500V AC for 1 minute
  • Product Type
  • Overload Relay
  • Insulation Resistance
  • > 100 M at 500V DC
  • Theory
  • Thermal Overload
  • Usage
  • Suitable for protection of electric motors against overload and phase failure
  • Contact Load
  • 6A (AC-15) / 3A (DC-13)
  • Operate Time
  • 1.2 Seconds (Standard)
  • Terminal Type
  • Screw Terminal
  • Rated Voltage
  • 690V AC
  • Supply Terminal
  • Top & Bottom Connect
  • Size
  • Standard Modular
  • Color
  • Black and Blue
  • Dimension (L*W*H)
  • Approx. 78mm x 45mm x 70mm
  • Weight
  • Approx. 120g
  • Operation Indicator
  • Trip indicator provided
  • Ampere Range
  • Available in multiple amp ranges e.g. 0.63A-1A, 1A-1.6A, 1.6A-2.5A, 2.5A-4A, 4A-6A, etc.
  • Complies With
  • IS/IEC 60947-4-1
  • Mounting Type
  • Direct mount to contactor/DIN Rail Mountable
  • Reset Type
  • Manual & Automatic Reset
  • Frequency
  • 50/60Hz
  • Enclosure
  • Flame Retardant Plastic
  • Tripping Class
  • Class 10A
  • Interlocking
  • Available for mechanical/electrical interlock
 

Multiple Amp Range LK MN2 Overload Relay Trade Information

  • Minimum Order Quantity
  • 10 Units
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 500 Units Per Month
  • Delivery Time
  • 10 Days
  • Main Domestic Market
  • All India
 

About Multiple Amp Range LK MN2 Overload Relay



Select the exceptional Multiple Amp Range LK MN2 Overload Relay and procure reliability for your electrical systems. This superlative product comes in a variety of amp ranges-making it a decorated choice for various protection needs. Designed for direct contactor/DIN rail mounting, it offers both manual and automatic reset options. Enjoy top-notch features such as operation indicators, phase failure protection, and compliance with IS/IEC 60947-4-1. Hot deal alert: experience more than 1,000,000 mechanical cycles, robust flame-retardant enclosure, and superior safety standards. Ideal for suppliers, traders, and wholesalers across India.

Versatile Applications for Commercial Settings

Multiple Amp Range LK MN2 Overload Relay is widely used by industrial experts, electricians, and maintenance engineers. Its adaptability makes it perfect for commercial settings such as factories, manufacturing units, and workshops. This relay is typically utilized to safeguard electric motors and machinery from overloads and phase failures, ensuring continuous operations. Whether used in new installations or retrofitting old systems, the device provides flexible protection compatible with varying currents, fitting diverse commercial and industrial usage scenarios.


Supply Details, Packaging, and Sample Logistics

We supply the Multiple Amp Range LK MN2 Overload Relay through dependable FOB ports across India. Each relay is securely packaged, adhering to robust industrial standards, ensuring safe delivery to customers. Our packaging details are tailored for bulk as well as individual orders. For queries about quotations or to request samples, our sample policy offers easy procedures for prospective buyers. Contact us to know about supply timelines and how you can receive detailed packaging options and prompt quotations.


FAQ's of Multiple Amp Range LK MN2 Overload Relay:


Q: How does the LK MN2 Overload Relay protect electric motors?

A: The LK MN2 Overload Relay safeguards electric motors by detecting overloads and phase failures, automatically tripping to prevent damage, and providing both manual and automatic reset options for continued protection.

Q: What is the process for selecting the correct amp range for my application?

A: To select the correct amp range, match your motor's rated current with one of the available ranges, such as 0.63A-1A, 1.6A-2.5A, or 4A-6A, ensuring precise overload protection and optimal performance for your equipment.

Q: Where can this relay be mounted for installation?

A: The LK MN2 Overload Relay can be directly mounted onto a contactor or attached to a DIN rail, offering flexibility and ease of installation for both compact and conventional panel setups.

Q: What are the commercial benefits of using this overload relay?

A: Commercial users benefit from enhanced motor safety, reduced downtime, mechanical/electrical interlock options, and a superlative mechanical life exceeding 1,000,000 cycles-all contributing to increased equipment reliability and operational efficiency.

Q: When should the operation indicator be checked on the device?

A: The operation (trip) indicator should be checked whenever a motor stops unexpectedly, as it signals overload conditions or phase failures, helping users diagnose issues rapidly and take corrective actions.

Q: What packaging and supply options are available for bulk orders?

A: For bulk procurement, the relays are individually packaged with robust protections, and supply is facilitated via major FOB ports. Detailed quotations and packaging options can be provided on request to meet specific customer requirements.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Electrical Relay Category

Multiple Range Amp LK MK1 Relay

Multiple Range Amp LK MK1 Relay

Minimum Order Quantity : 10 Units

Theory : Other , Electromagnetic Relay

Color : Grey/Black

Contact Form : 1 NO+1 NC

Mechanical Life : >10 Million Operations

Coil Voltage : 110 V AC/DC

ABB Overload Relay

ABB Overload Relay

Minimum Order Quantity : 10 Units

Theory : Other , Thermal Overload Protection

Color : Gray

Contact Form : 1 NO + 1 NC

Mechanical Life : Over 10 Million Operations

Coil Voltage : N/A (No coil, directly actuated)

Pin Type Omron Relay

Pin Type Omron Relay

Minimum Order Quantity : 10 Units

Theory : Other , Electromagnetic Relay

Color : Transparent / Black

Contact Form : SPDT (1C), DPDT (2C) options

Mechanical Life : 10,000,000 operations min.

Coil Voltage : 6V, 12V, 24V, 48V, 110V, 220V (DC/AC as per model)

LK MN5 Overload Relay

LK MN5 Overload Relay

Minimum Order Quantity : 10 Units

Theory : Thermal Relay

Color : Black & White

Contact Form : 1NO+1NC

Mechanical Life : 1,000,000 operations

Coil Voltage : Direct Control



Back to top